Creeaza.com - informatii profesionale despre


Simplitatea lucrurilor complicate - Referate profesionale unice
Acasa » scoala » fizica
Filtre LCate pe baza parametrilor de lucru

Filtre LCate pe baza parametrilor de lucru


Filtre LC proiectate pe baza parametrilor de lucru

Scopul lucrarii

Masuratori asupra unor filtre LC obtinute prin sinteza pe baza parametrilor de lucru si anume, gabaritul alimentarii de lucru si resistentzele de terminatie.

Desfasurarea lucrarii

A) pt circuitul din fig 1c



f(kHz)

U2(V)

│HC(f)│

│HC(f)│ =2U2/E* Rg/Rs  unde Rg=Rs=Rc=600Ω

E=2V

→0.692→ft

B)

ft=57.6khz => ω =361.72kHz

R=600Ω

L= (2*600/361.72) *10-3=3.31mH

C=[1/(600*361.72)]*10-3=4.60*10-9=4.60nF

C)

Ft=57.6kHz

F(kHz)

t0(μs)

φt

=-360 t0f0

φt=arctg(2*f/ft-f3/ft3)/(1-2f2/ft2)

D)pt circuitul din fig.2b)

E=2V;Rg=600 ;Rs=1200 ;Rc=Rg

f(kHz)

0.1

0.5

1

5

10

20

30

50

70

80

90

U2(v)

1.317

1.317

1.315

1.313

1.315

1.322

1.327

1.313

1.17

1.02

0.85

|Hc(f)|

0.931

0.931

0.925

0.928

0.929

0.934

0.938

0.928

0.827

0.721

0.601

E)

Ft=85.5kHz => =563.94kHz

R=2R0=1200Ω

L=3*600*10-3/563.94=3.19 μF

C1=1*10-3/(600*563.94)=2.95nF

C2=1/2*C1=1.47nF

F)ft=85.5kHz

f(kHz)

t0(μs)

φt

G) pt circuitul din fig 3B

f(kHz)

U2(V)

|HC(F)|

H) ft=31.85kHz =>  ω 200.01kHz

R=600

L=600*10-3/200.01=2.99mH

C=2*10-3/(600*200.01)=8.33nF

I) ft=31.85kHz

f(kHz)

3.185

5.308

7.96

10.61

18.38

31.85

55.16

95.55

187.4

191.1

318.5

t0

14

12.6

12.8

12.8

12.6

15

11.6

7.4

5.4

3.8

2.4

-14.05

-24.08

-36.6

-48.9

-76.75

-172

-230.3

-254.5

-247.6

-261.4

275.3

φt

-11.47

-19.18

-28.9

-38.58

-70.85

-45

-19.09

-51

-61.03

-70.81

78.52

J) pt circuitul din figura 5

f(kHz)

t0(μs)

HC(f)

K)

ft=57,2kHz

R=R0=600Ω

L=112*600/359,21=0,83mH

C1=C2=1*10-3/600*359,21=4,63*10-9=4,63μF





Politica de confidentialitate